Fluo-4 AM is a fluorescent dye (λex=494 nm, λem=516 nm). Preloaded with Fuo-4 AM, a very bright fluorescence image is observed. In a parallel experiment with fluo-3 AM-loaded cells, the resulting fluorescence image, although clearly discernable in this case, is less bright.
Species | Mouse | Rat | Rabbit | Guinea pig | Hamster | Dog |
Weight (kg) | 0.02 | 0.15 | 1.8 | 0.4 | 0.08 | 10 |
Body Surface Area (m2) | 0.007 | 0.025 | 0.15 | 0.05 | 0.02 | 0.5 |
Km factor | 3 | 6 | 12 | 8 | 5 | 20 |
Animal A (mg/kg) = Animal B (mg/kg) multiplied by | Animal B Km |
Animal A Km |
For example, to modify the dose of Compound A used for a mouse (20 mg/kg) to a dose based on the BSA for a rat, multiply 20 mg/kg by the Km factor for a mouse and then divide by the Km factor for a rat. This calculation results in a rat equivalent dose for Compound A of 10 mg/kg.
Molecular Weight | 1096.94 |
Formula | C51H50F2N2O23 |
CAS Number | 273221-67-3 |
Purity | >95% |
Solubility | DMSO |
Storage | -20°C, dry, protect from light, sealed |
[1] Lina Qiu, et al. Staining the Cytoplasmic Ca2+ with Fluo-4/AM in Apple Pulp
[5] Odmara L Barreto-Chang, et al. Calcium imaging of cortical neurons using Fura-2 AM
Related Fluorescent Dye Products |
---|
Tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II) dichloride
Tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II) dichloride is an oxygen-sensitive fluorescence indicator widely used as a probe for luminescence detection and oxygen quantification. The maximum absorption wavelength is max 455 nm and the maximum luminescence is λmax 613 nm. |
FeRhoNox-1 (Fe2+ indicator)
FeRhoNox-1, also known as RhoNox-1, is an active fluorescent probe that specifically detects unstable iron (1) ions (Fe2+). After the reaction of -denier with Fe2+, -orange (red) fluorescent products are irreversibly generated. (Absmax= 540nm, FLmax= 575nm). |
CMFDA
CMFDA is a cell-permeable fluorescent probe that can be used as a cellular tracer. CMFDA can be cleaved by non-specific esterases common to living cells, producing a fluorescent compound, fluorescein, visible using a fluorescent microscope. |
Lyso-Tracker Red
Lyso-Tracker Red is an eosinophilic fluorescent probe with a maximum excitation wavelength of 577nm and a maximum emission wavelength of 590nm. Lyso-Tracker Red must be at very low concentrations (usually about 50nM) to achieve excellent selectivity. |
FITC-Dextran (MW 10000)
FITC-Dextran (MW 10000) is a fluorescent probe for fluorescein isothiocyanate (FITC) dextran (Ex=495 nm; Em=525 nm). |