FITC-Dextran (MW 10000) is a fluorescent probe for fluorescein isothiocyanate (FITC) dextran (Ex=495 nm; Em=525 nm). FITC-Dextran (MW 10000) can be used as a marker to reveal heat shock-induced cell damage and to study the early and late stages of apoptosis. FITC-Dextran (MW 10000) can also be used for cell permeability studies, such as blood-brain barrier permeability and determination of the extent of blood-brain barrier disruption.
Species | Mouse | Rat | Rabbit | Guinea pig | Hamster | Dog |
Weight (kg) | 0.02 | 0.15 | 1.8 | 0.4 | 0.08 | 10 |
Body Surface Area (m2) | 0.007 | 0.025 | 0.15 | 0.05 | 0.02 | 0.5 |
Km factor | 3 | 6 | 12 | 8 | 5 | 20 |
Animal A (mg/kg) = Animal B (mg/kg) multiplied by | Animal B Km |
Animal A Km |
For example, to modify the dose of Compound A used for a mouse (20 mg/kg) to a dose based on the BSA for a rat, multiply 20 mg/kg by the Km factor for a mouse and then divide by the Km factor for a rat. This calculation results in a rat equivalent dose for Compound A of 10 mg/kg.
Molecular Weight | |
Formula | |
CAS Number | 60842-46-8 |
Purity | MW. ~10000 |
Solubility | Water 50 mg/mL |
Storage | 4°C, protect from light, dry, sealed |
Related Fluorescent Dye Products |
---|
Tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II) dichloride
Tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II) dichloride is an oxygen-sensitive fluorescence indicator widely used as a probe for luminescence detection and oxygen quantification. The maximum absorption wavelength is max 455 nm and the maximum luminescence is λmax 613 nm. |
FeRhoNox-1 (Fe2+ indicator)
FeRhoNox-1, also known as RhoNox-1, is an active fluorescent probe that specifically detects unstable iron (1) ions (Fe2+). After the reaction of -denier with Fe2+, -orange (red) fluorescent products are irreversibly generated. (Absmax= 540nm, FLmax= 575nm). |
CMFDA
CMFDA is a cell-permeable fluorescent probe that can be used as a cellular tracer. CMFDA can be cleaved by non-specific esterases common to living cells, producing a fluorescent compound, fluorescein, visible using a fluorescent microscope. |
Lyso-Tracker Red
Lyso-Tracker Red is an eosinophilic fluorescent probe with a maximum excitation wavelength of 577nm and a maximum emission wavelength of 590nm. Lyso-Tracker Red must be at very low concentrations (usually about 50nM) to achieve excellent selectivity. |
ICG-OSu
ICG-OSu (ICG NHS ester) is a near infrared fluorescent agent with amine reactivity that is widely used in the design of in vivo imaging probes. Em >750 nm infrared, Ex >750 nm infrared. |
Products are for research use only. Not for human use. We do not sell to patients.